PGN Protocol Specification

Overview

AgOpenGPS uses a custom PGN (Parameter Group Number) protocol for UDP communication between AgIO and the main application. The protocol wraps data in a specific format with headers, PGN identifier, length, data payload, and CRC checksum.

PGN Byte Structure

Byte Description Value
0 Standard AOG header 0x80
1 PGN header 0x81
2 Source address 0x7F
3 PGN identifier varies
4 Data length varies
5+ Data payload varies
N CRC checksum sum of bytes 2 to N-1

Example PGN structure:

[0x80, 0x81, 0x7F, PGN, Length, Data..., CRC]

CRC Calculation

The CRC is a simple checksum calculated as the sum of bytes from index 2 (source address) through the last data byte:

byte crc = 0;
for (int i = 2; i < pgn.Length - 1; i++)
{
    crc += pgn[i];
}
pgn[pgn.Length - 1] = (byte)crc;

UDP Network Configuration

Parameter Value
AOG Listen Port 15555 (loopback)
AgIO Endpoint 127.255.255.255:17777
Protocol UDP
Subnet 127.x.x.x (loopback)

Connection setup:

// AOG binds to loopback port 15555
loopBackSocket.Bind(new IPEndPoint(IPAddress.Loopback, 15555));

// Send to AgIO on 127.255.255.255:17777
EndPoint epAgIO = new IPEndPoint(IPAddress.Parse("127.255.255.255"), 17777);

PGN Messages

Receiving PGNs (from AgIO)

PGN 0xD6 (214) - GPS Position Data

Length: 52 bytes

Bytes Field Type Description
5-12 Longitude double GPS longitude
13-20 Latitude double GPS latitude
21-24 Heading Dual float Dual antenna heading (or MaxValue)
25-28 Heading True float Single antenna heading
29-32 Speed float Ground speed
33-36 Roll float IMU roll angle
37-40 Altitude float GPS altitude
41-42 Satellites ushort Number of satellites
43 Fix Quality byte GPS fix quality
44-45 HDOP ushort Horizontal dilution of precision
46-47 Age ushort Data age
48-49 IMU Heading ushort External IMU heading
50-51 IMU Roll short External IMU roll
52-53 IMU Pitch short External IMU pitch
54-55 IMU Yaw Rate short Angular velocity

Special values:

  • double.MaxValue / float.MaxValue = data not available
  • ushort.MaxValue / short.MaxValue = sensor not connected

PGN 0xD3 (211) - External IMU Data

Length: 8 bytes

Bytes Field Type Description
5-6 Heading Int16 IMU heading (div 10 for degrees)
7-8 Roll Int16 IMU roll (div 10 for degrees)
9-10 Angular Velocity Int16 Rotation rate (div -2)

PGN 0xD4 (212) - IMU Disconnect

Length: 6 bytes

Bytes Field Type Description
5 Disconnect byte 1 = IMU disconnected

PGN 253 (0xFD) - Steer Module Response

Length: 14 bytes

Bytes Field Type Description
5-6 Actual Steer Angle Int16 Sensor reading (div 100 for degrees)
7-8 Heading Int16 Module heading (9999 = N/A)
9-10 Roll Int16 Module roll (8888 = N/A)
11 Switch Status byte Bit 0 = work switch, Bit 1 = steer switch
12 PWM byte Actual PWM output

PGN 250 (0xFA) - Sensor Data

Length: 6 bytes

Bytes Field Type Description
5 Sensor Data byte Raw sensor value

PGN 234 (0xEA) - Remote Switches

Length: 14 bytes

Bytes Field Type Description
5-12 Switch Data byte[8] Section switch states

PGN 221 (0xDD) - Display Message

Length: variable

Bytes Field Type Description
4 Length byte Number of bytes
5 Display Time byte Seconds to display
6 Color byte 0 = Salmon, other = Bisque
7+ Message UTF-8 Text message

PGN 222 (0xDE) - Remote Commands

Length: 7 bytes

Bytes Field Type Description
5 Mask byte Command mask
6 Command byte Command value

Commands:

  • Bit 0: Nudge line (0 = left, 1 = right)
  • Bit 1: Cycle line (0 = forward, 1 = backward)

PGN 0xF0 (240) - ISOBUS Heartbeat (TC→AOG)

Length: variable (min 2 data bytes)

Bytes Field Type Description
5 Status byte Bit 0 = section control enabled, Bits 1-3 = number of clients (0-7)
6 Num Sections byte Number of sections (0 = no implement)
7+ Section States byte[] Bitmask per section, 1 bit per section

Sending PGNs (to AgIO/Steer Module/TC)

PGN 0xF1 (241) - Section Control Enable Request (AOG→TC)

Length: 7 bytes

Bytes Field Type Description
5 Enabled byte 0x01 = enable, 0x00 = disable

PGN 0xF2 (242) - Process Data (AOG→TC)

Length: 12 bytes

Bytes Field Type Description
5-6 Identifier ushort Process data identifier (513 = guidance deviation, 397 = speed, 597 = total distance)
7-10 Value int32 Process data value

PGN 0xF3 (243) - Field Name (AOG→TC)

Length: variable

Bytes Field Type Description
4 Length byte Number of name bytes (0 = field closed, max 248)
5+ Name UTF-8 Active field folder name

Sent when:

  • Field is opened or changed
  • Field is closed (length = 0)
  • TC reconnects after >1s absence (current state, open or closed)

PGN 0xD0 (208) - Latitude/Longitude

Length: 14 bytes

byte[] latLong = new byte[] { 0x80, 0x81, 0x7F, 0xD0, 8, 0, 0, 0, 0, 0, 0, 0, 0, 0xCC };

Encoding:

int encodedAngle = (int)(lat * (0x7FFFFFFF / 90.0));
int encodedAngle = (int)(lon * (0x7FFFFFFF / 180.0));

PGN 0xFE (254) - AutoSteer Data

Length: 14 bytes

Byte Index Field Description
5 Speed Lo Speed low byte
6 Speed Hi Speed high byte
7 Status AutoSteer status
8 Steer Angle Lo Commanded steer angle low
9 Steer Angle Hi Commanded steer angle high
10 Line Distance Distance from guidance line
11 Section Control 1-8 Bitmask for sections
12 Section Control 9-16 Bitmask for sections

PGN 0xFC (252) - AutoSteer Settings

Length: 14 bytes

Byte Index Field Description
5 Gain Proportional Kp value
6 High PWM Maximum PWM
7 Low PWM Minimum PWM when driving
8 Min PWM Absolute minimum PWM
9 Counts Per Degree WAS sensor counts
10 WAS Offset Lo Low byte
11 WAS Offset Hi High byte
12 Ackerman Ackerman compensation

PGN 0xFB (251) - AutoSteer Config

Length: 14 bytes

Byte Index Field Description
5 Set0 Configuration byte 0
6 Max Pulse Maximum pulse count
7 Min Speed Minimum speed for steering
8 Ackerman Fix Ackerman fix value
9 Angular Velocity Max angular velocity

PGN 0xEF (239) - Machine Data

Length: 14 bytes

Byte Index Field Description
5 U-Turn U-Turn state
6 Speed Vehicle speed
7 Hyd Lift Hydraulic lift state
8 Tram Tramline state
9 Geo Stop Geofence stop
11 Section Control 1-8 Section states
12 Section Control 9-16 Section states

PGN 0xEE (238) - Machine Config

Length: 14 bytes

Byte Index Field Description
5 Raise Time Hydraulic raise time
6 Lower Time Hydraulic lower time
7 Enable Hyd Hydraulics enabled
8 Set0 User setting 0
9 User1 User defined 1
10 User2 User defined 2
11 User3 User defined 3
12 User4 User defined 4

PGN 0xEC (236) - Relay Config

Length: 29 bytes

Byte Index Field Description
5-28 Pin Config Pin configuration for 24 relays

Pin config format: Comma-separated string "1,2,3,0,..." converted to bytes.

PGN 0xEB (235) - Section Dimensions

Length: 38 bytes

Byte Index Field Description
5-6 Section 0 Width for section 0 (Lo, Hi)
7-8 Section 1 Width for section 1
... ... ...
35-36 Section 15 Width for section 15
37 Num Sections Number of sections

PGN 0xE5 (229) - Section Control (Extended)

Length: 16 bytes

Byte Index Field Description
5 Section 1-8 Bitmask
6 Section 9-16 Bitmask
7 Section 17-24 Bitmask
8 Section 25-32 Bitmask
9 Section 33-40 Bitmask
10 Section 41-48 Bitmask
11 Section 49-56 Bitmask
12 Section 57-64 Bitmask
13 Tool Left Speed Left tool speed
14 Tool Right Speed Right tool speed

PGN 0xE4 (228) - Rate Control

Length: 14 bytes

Byte Index Field Description
5 Rate 0 Rate setting 0
6 Rate 1 Rate setting 1
7 Rate 2 Rate setting 2

4-Second Timeout Mechanism

GPS_Out uses a 4-second timeout for NMEA sentence forwarding:

// If no valid GPS data for 4 seconds, stop sending
if (age > 4.0) {
    // Stop output
}

This prevents stale data from being sent to external devices.

Integration Example

// Sending PGN to AgIO
public void SendPgnToLoop(byte[] byteData)
{
    if (loopBackSocket != null && byteData.Length > 2)
    {
        // Calculate CRC
        int crc = 0;
        for (int i = 2; i + 1 < byteData.Length; i++)
        {
            crc += byteData[i];
        }
        byteData[byteData.Length - 1] = (byte)crc;

        // Send to endpoint
        loopBackSocket.BeginSendTo(byteData, 0, byteData.Length,
            SocketFlags.None, epAgIO, SendAsyncLoopData, null);
    }
}
// Receiving PGN from AgIO
private void ReceiveFromAgIO(byte[] data)
{
    // Validate header
    if (data.Length > 4 && data[0] == 0x80 && data[1] == 0x81)
    {
        // Validate CRC
        int Length = Math.Max((data[4]) + 5, 5);
        byte CK_A = 0;
        for (int j = 2; j < Length; j++)
        {
            CK_A += data[j];
        }

        if (data[Length] != (byte)CK_A)
        {
            return; // CRC mismatch
        }

        // Process by PGN
        switch (data[3])
        {
            case 0xD6: // GPS Position
                // Process...
                break;
            // ... other PGNs
        }
    }
}

Related Files

  • Forms/UDPComm.Designer.cs - UDP communication implementation
  • Forms/PGN.Designer.cs - PGN message definitions
  • Classes/CISOBUS.cs - ISOBUS PGN handling