Hardware RAID controllers (MegaRAID, HP SmartArray, Adaptec, 3ware, Areca, HPT) sit between the operating system and the physical drives. The OS sees a single logical disk (the RAID volume), not the individual drives behind it. smartctl --scan finds the logical disk but can't read SMART data from it -- SMART lives in the firmware of each physical drive, and the RAID controller blocks direct access by default.
To reach the physical drives, smartctl needs a RAID-specific device type flag (-d megaraid,0, -d cciss,0, etc.) that tells it to talk through the controller's passthrough interface. SMART Sniffer supports this via device_overrides in your config.
--discover does not probe RAID controllers yet. Discovery finds drives that the OS exposes directly. Drives behind hardware RAID are hidden from the OS and require manual configuration. RAID probing is on the roadmap but not yet implemented.
Software RAID (mdraid, LVM, ZFS) is different. Software RAID uses standard block devices (/dev/sdX). The drives are visible to the OS and smartctl reads them normally. You don't need device_overrides for software RAID -- the agent picks them up automatically.
Find out what RAID controller you have:
# Linux -- check PCI devices
lspci | grep -i raid
# Or check for loaded kernel modules
lsmod | grep -iE "megaraid|cciss|3w-|arcmsr|hpsa"Common output and what it means:
lspci output contains |
Controller family | smartctl device type |
|---|---|---|
| MegaRAID, LSI, Avago, Broadcom | MegaRAID | megaraid,N |
| Smart Array, HP, HPE | HP SmartArray | cciss,N |
| 3ware, AMCC | 3ware | 3ware,N |
| Areca, ARC-xxxx | Areca | areca,N or areca,N/E |
| HighPoint, HPT | HighPoint | hpt,L/M/N |
N is the drive index (starting at 0). Each physical drive behind the controller gets its own index.
Each controller family has its own CLI tool for listing physical drives. You don't strictly need these tools -- you can also probe by incrementing the index until smartctl returns an error -- but they make life easier.
# If you have storcli or MegaCli installed:
storcli /c0 /eall /sall show
# or
MegaCli -PDList -aALL | grep -E "Slot|Device Id"
# Without vendor tools, just probe incrementally:
sudo smartctl -d megaraid,0 -i /dev/sda
sudo smartctl -d megaraid,1 -i /dev/sda
sudo smartctl -d megaraid,2 -i /dev/sda
# ... keep going until "No such device"The device path (/dev/sda) is the logical RAID volume. All drives behind the controller are accessed through the same path with different indices.
# If you have ssacli (or the older hpacucli):
ssacli ctrl all show config detail | grep -E "physicaldrive|Port|Bay"
# Probe incrementally:
sudo smartctl -d cciss,0 -i /dev/sda
sudo smartctl -d cciss,1 -i /dev/sda# If you have tw_cli:
tw_cli /c0 show
# Probe incrementally:
sudo smartctl -d 3ware,0 -i /dev/twl0
sudo smartctl -d 3ware,1 -i /dev/twl0Note: 3ware uses /dev/twlN or /dev/twaN device paths, not /dev/sdX.
# Probe incrementally:
sudo smartctl -d areca,1 -i /dev/sg0
sudo smartctl -d areca,2 -i /dev/sg0Areca uses 1-based indexing (starts at 1, not 0). Multi-enclosure setups use the /E suffix: areca,1/2 means drive 1 on enclosure 2.
Once you know your controller type and drive count, verify SMART data is readable:
# Replace with your controller type and device path
sudo smartctl -d megaraid,0 -a /dev/sdaYou should see full SMART output -- model, serial, attributes, health status. If you get an error about "device open failed" or "Unknown USB bridge," the device type or index is wrong.
Test every drive. Don't assume all drives use the same path. Some controllers expose drives on different logical volumes.
Add a device_overrides section to your config.yaml with one entry per physical drive:
device_overrides:
- device: /dev/sda
protocol: megaraid,0
- device: /dev/sda
protocol: megaraid,1
- device: /dev/sda
protocol: megaraid,2
- device: /dev/sda
protocol: megaraid,3Each entry maps a device path to the smartctl -d protocol string. The agent treats overridden devices as first-class drives even if they are not found by smartctl --scan.
Multiple controllers: If you have more than one RAID controller (e.g., two MegaRAID cards), each has its own logical volume (/dev/sda, /dev/sdb). Map each drive to the correct logical volume path.
device_overrides:
# Controller 1 (/dev/sda)
- device: /dev/sda
protocol: megaraid,0
- device: /dev/sda
protocol: megaraid,1
# Controller 2 (/dev/sdb)
- device: /dev/sdb
protocol: megaraid,0
- device: /dev/sdb
protocol: megaraid,1device_overrides:
- device: /dev/sda
protocol: cciss,0
- device: /dev/sda
protocol: cciss,1device_overrides:
- device: /dev/twl0
protocol: 3ware,0
- device: /dev/twl0
protocol: 3ware,1device_overrides:
- device: /dev/sg0
protocol: areca,1
- device: /dev/sg0
protocol: areca,2sudo systemctl restart smartha-agentCheck the agent health endpoint to confirm drives are detected:
curl http://localhost:9099/api/health
curl http://localhost:9099/api/drivesEach physical drive behind the RAID controller should appear as its own device in Home Assistant with full SMART data.
The device path or protocol string is wrong. Double-check:
- Is the device path correct? (
/dev/sdafor MegaRAID/SmartArray,/dev/twl0for 3ware,/dev/sg0for Areca) - Is the drive index correct? Try incrementing or decrementing.
- Does smartctl work manually? Run
sudo smartctl -d megaraid,0 -a /dev/sdadirectly.
The agent is finding the logical RAID volume (the virtual disk) instead of the physical drives. The logical volume doesn't have SMART data. Make sure your device_overrides point to individual physical drives using the RAID-specific protocol string.
You probably have more physical drives than the indices you configured. Probe higher indices until smartctl returns an error, then add all valid indices to your config.
The agent needs root access (or appropriate capabilities) to send RAID passthrough commands. The default systemd service runs as root. If you've changed the service user, make sure it has access to the RAID device nodes.
Some RAID controllers can be set to JBOD (Just a Bunch of Disks) mode, which presents each drive directly to the OS without a RAID layer. In JBOD mode, drives appear as standard /dev/sdX devices and smartctl --scan finds them normally. No device_overrides needed. Check your controller's BIOS/firmware settings if you prefer this approach.
| Controller | Device type | Device path | Indexing | Notes |
|---|---|---|---|---|
| MegaRAID / LSI / Broadcom | megaraid,N |
/dev/sdX |
0-based | Most common in homelab servers |
| HP SmartArray | cciss,N |
/dev/sdX |
0-based | HPE ProLiant servers |
| 3ware / AMCC | 3ware,N |
/dev/twlN or /dev/twaN |
0-based | Older controllers, still in use |
| Areca | areca,N or areca,N/E |
/dev/sgN |
1-based | /E suffix for multi-enclosure |
| HighPoint | hpt,L/M/N |
/dev/sdX |
L=controller, M=channel, N=target | Less common |
- Drive Discovery (
--discover) -- automated drive detection (does not yet probe RAID controllers) - Platform Install Paths -- where the agent and config live on each platform