- GuiCommand:
Name:FEM EquationFlow
MenuLocation: Solve → Flow equation
Workbenches:[FEM](FEM_Workbench.md)
Version:0.19
SeeAlso:
---
This equation calculate viscous fluid flows using the Navier-Stokes equations.
For info about the math of the equation, see the Elmer models manual, section Navier-Stokes Equations.
- After adding an Elmer solver as described here, select it in the tree view.
- Now either use the toolbar button
or the menu Solve → Flow equation.
- Change the equation's solver settings or the general solver settings if necessary.
For the general solver settings, see the Elmer solver settings.
The flow equation provides these special settings:
-
Div Discretization: To be set to true for incompressible flow for more stable discretization when the Reynolds number increases.
-
Flow Model: The flow model that should be used. The default Full includes convection and time derivative terms in the model. No convection switches off the convection terms and the Stokes model switches off the convection terms and the (explicit) time derivative terms.
-
Gradp Discretization: If set to true pressure Dirichlet boundary conditions can be used. Also the mass flux is available as a natural boundary condition.
-
Variable: Optional only for calculations in 2D: You can change the default of 3 to 2.Note: In this case none of the flow velocity constraints can have a specified z-component.
Equation:
-
Convection: The type of convection to be used in the
Heat equation.Note: For thermal flows it must be set to Computed (the default).
-
Magnetic Induction: If set to true the magnetic induction equation will be solved along with the Navier-Stokes equations.
The electrostatic equation takes the following constraints into account if they are set:
Constraint flow velocity
Constraint initial flow velocity
Constraint pressure
Constraint initial pressure ((v1.0) )
- Except for calculations in 2D, for all above constraints it is important that they act on a face or body. Constraints for 3D set to lines or vertices are not recognized by the Elmer solver.
- Since
Constraint pressure can only be set to faces, pressure constraints cannot be used for calculations in 2D.
- If there is no
Constraint pressure set,
Constraint initial pressure will only be taken into account if Gradp Discretization is set to true.
The results are the velocity in Constraint initial pressure and
Constraint pressure constraint given, the resulting pressure will be relative not absolute. Since a pressure must act on a face, absolute pressure results cannot be obtained in 2D simulations.
{{FEM Tools navi}}
documentation index > FEM > FEM EquationFlow