BWT Device Error Codes

37 error codes (IDs are not contiguous: 1-88 range). Returned as comma-separated list in ActiveErrorIDs field. ShowError: 0=OK (blue LED), 1=Warning (yellow), 2=Error (red).

ID Type Meaning Description
1 Error Motor / Valve 1 Cannot be controlled
2 Error Motor / Valve 2 Cannot be controlled
3 Error Blending motor Cannot be controlled
5 Warning Regenerative almost empty Fill level <= 20%
8 Error Overcurrent Motor/Valve 1 Power consumption too high
9 Error Overcurrent Motor/Valve 2 Power consumption too high
10 Error Overcurrent Motor/Valve 3 Power consumption too high
12 Error Overcurrent solenoid valve Power consumption too high
13 Error AQA Stop Volume Set volume exceeded
14 Error AQA Stop Sensor Floor sensor triggered
15 Warning AQA Watch Continuous flow detected
16 Warning Pressure switch Line pressure dropped
21 Error Piston 1/2 position Undefined position
22 Error Internal electronics Internal error
25 Warning Regenerative volume not reached Too little brine drawn
26 Error AQA Guard Wireless Sensor Wireless floor sensor triggered
27 Error Regenerative empty Fill level = 0%
32 Warning Routine maintenance due Customer maintenance needed
33 Warning Inspection due Customer inspection needed
34 Warning Expert maintenance due Service technician needed
35 Warning Mineral container almost empty Dosing unit (Hybrid)
36 Warning Mineral container empty Dosing unit (Hybrid)
43 Error Valve overcurrent Solenoid valve
44 Error Valve overcurrent Solenoid valve
45 Error Dosing pump valve Power consumption too high
46 Error Ball valve Motorized ball valve overcurrent
54 Warning Water meter not counting No pulses for 30 days
55 Warning Regeneration disturbed Repeatedly no brine drawn
56 Error PCB 1.0 init error Could not be initialized
57 Error PCB 1.1 init error Could not be initialized
58 Error Motor 1 position error Faulty position
59 Error Motor 2 position error Faulty position
61 Warning Conductivity too high Measured conductivity
62 Warning Conductivity limit 1 Exceeds limit 1
63 Warning Conductivity limit 2 Exceeds limit 2
64 Warning Conductivity water limit Exceeds water limit
65 Error No function No brine available
66 Warning Temperature sensor disconnected Connection broken
67 Warning Temperature too high Measured temperature
68 Error Ball valve not responding Not responding
74 Warning Replace/flush filter External filter reminder
75 Warning Brine not saturated Lower capacity
88 Warning Dosing pump malfunction Malfunction present