Human-readable release notes for OpenELIS Global, written for three audiences: decision-makers, implementers & admins, and lab users. This file is generated from the OpenELIS features inventory (do not hand-edit).

See also: the live product roadmap (https://uwdigi.atlassian.net/wiki/spaces/oeg/pages/640319495), the per-audience release-notes page (https://uwdigi.atlassian.net/wiki/spaces/oeg/pages/1412136974), and earlier releases v3.0/v2.7/v2.6 (https://uwdigi.atlassian.net/wiki/spaces/OG/pages/645005332).

v3.2 (beta stream — 3.2.1.x, pilot / UAT)

3.2.1.10

For decision-makers

  • Full two-way instrument integration reduces manual order entry at the bench. (OGC-773) — Outbound order dispatch

For implementers & admins

  • New live log screen and logging configuration, including under SSO login. — System monitoring & logs
  • Bidirectional ASTM/HL7 order dispatch via the analyzer bridge. (OGC-773) — Outbound order dispatch

For lab users

  • Orders can now be sent to instruments automatically, not just received. (OGC-773) — Outbound order dispatch

3.2.1.9

For decision-makers

  • Operational visibility into data exchange reliability. — Automatic result sharing (FHIR)

For implementers & admins

  • See and act on FHIR data-export retry health from admin. — Automatic result sharing (FHIR)
  • Filter and manage test notifications more easily. — Test notifications & SMS gateways

3.2.1.8

For lab users

  • Patient identifiers now show in the modify-order header. — Patient & order enhancements
  • Entered date/time now persists on result entry. — Results entry

3.2.1.7

For decision-makers

  • Supports consent-tracking compliance for patient testing. (OGC-557, OGC-558) — Informed consent capture
  • Stronger quality control supports accreditation readiness. (OGC-41) — Westgard QC rules & dashboard
  • Modernized, faster UI foundation. — Modernized user interface

For implementers & admins

  • Manual consent recording fields configurable on patient orders. (OGC-557, OGC-558) — Informed consent capture
  • FHIR-based QC pipeline with automated rule evaluation. (OGC-41) — Westgard QC rules & dashboard
  • Create file-based analyzers from profiles with two-way bridge sync. — Analyzer file import
  • Breaking change to query translation — review analyzer query configuration on upgrade. [breaking] (OGC-346) — Analyzer integration framework

For lab users

  • Record patient informed consent against an order. (OGC-557, OGC-558) — Informed consent capture
  • QC results are evaluated automatically against Westgard rules. (OGC-41) — Westgard QC rules & dashboard
  • Cleaner, faster storage screens. — Sample storage management

3.2.1.6

For lab users

  • Attach patient ID documents to records. — Patient & order enhancements

3.2.1.5

For decision-makers

  • Chain-of-custody for sample referral networks. (OGC-62) — Sample shipment & referral
  • Audit trail supports accreditation and data integrity. — System-level audit trail
  • 21 CFR Part 11-aligned electronic signatures. — Electronic signatures
  • Structured CAPA supports quality management. — Non-conforming events (NCE) & CAPA
  • Security hardening across the REST API. [security] (OGC-150) — Strengthened data security
  • TAT monitoring surfaces lab performance. (OGC-306, OGC-307) — Turnaround time report & dashboard
  • Expanded FHIR R4 surface for interoperability. — FHIR R4 API
  • Supports multilingual deployments. (OGC-349) — Standardized terminology
  • Broader instrument coverage. (OGC-344, OGC-417, OGC-418) — Analyzer file import

For implementers & admins

  • System-wide audit trail of configuration and data changes. — System-level audit trail
  • Project-wide CSRF and REST @PreAuthorize hardening — re-test custom integrations. [security] (OGC-150) — Strengthened data security
  • Metadata can be translated into any language. (OGC-349) — Standardized terminology
  • Added flat-file import for additional instruments. (OGC-344, OGC-417, OGC-418) — Analyzer file import

For lab users

  • Create electronic shipment manifests for referred samples. (OGC-62) — Sample shipment & referral
  • Sign results and reports electronically. — Electronic signatures
  • Track non-conforming events with history and assignment. — Non-conforming events (NCE) & CAPA
  • Monitor turnaround times; manage the lab calendar. (OGC-306, OGC-307) — Turnaround time report & dashboard
  • Order entry and sample collection are now separate steps. (OGC-356) — Order & sample entry

3.2.1.4

For decision-makers

  • Connect instruments without custom code. (OGC-325, OGC-492) — Analyzer integration framework
  • Validated TB/HIV/COVID instrument support. (OGC-335) — Validated instrument library
  • Patient/provider SMS notifications in more regions. — Test notifications & SMS gateways
  • Brings EQA into the LIS for accreditation. — EQA / proficiency testing
  • Foundation for flexible, self-service reporting. — Custom data export

For implementers & admins

  • Generic, bridge-mandatory analyzer framework with per-analyzer mappings. (OGC-325, OGC-492) — Analyzer integration framework
  • Cepheid GeneXpert ASTM adapter. (OGC-335) — Validated instrument library
  • Configure Twilio or Africa's Talking for SMS. — Test notifications & SMS gateways

For lab users

  • Control how many barcode labels print. (OGC-284) — Barcode label management
  • Begin managing proficiency-testing events in OpenELIS. — EQA / proficiency testing