Skip to content

Discovery Problem #15

Description

@mkolobok72

The HP server has two controllers.
Disks are connected to one, but not to the second.

Utility output for the first controller
/usr/sbin/hpacucli ctrl slot=0 ld all show

Smart Array P410i in Slot 0 (Embedded)
array A
logicaldrive 1 (1.1 TB, RAID 1+0, OK)

Utility output for the second controller
/usr/sbin/hpacucli ctrl slot=3 ld all show
Error: The specified device does not have any logical drives.

Output of your utility's disk definitions

/opt/raidstat/raidstat --vendor hp -d ct
{"data":[{"{#CT_ID}":"3"},{"{#CT_ID}":"0"}]}

/opt/raidstat/raidstat --vendor hp -d pd
Error executing command '/usr/sbin/hpacucli ctrl slot=3 pd all show': exit status 1

/opt/raidstat/raidstat --vendor hp -d ld
Error executing command '/usr/sbin/hpacucli ctrl slot=3 ld all show': exit status 1

Instead of a general error, your utility should show disks from the first controller and ignore the error on the second