Fluxion v0.7.0-alpha - Thermal Physics Complete

Latest

Choose a tag to compare

@anchapin anchapin released this 02 Apr 21:27

What’s New

  • Symmetric thermal mass correction for high-mass buildings
  • Full ASHRAE 140 validation suite (18 cases)
  • CTF (Conduction Transfer Function) solver for high-mass buildings
  • Finite difference solver as fallback option
  • Automatic method selection based on thermal time constant

Bug Fixes

  • Case 900 cooling energy underestimation (-33.76% → within ±15% tolerance)
  • Asymmetric thermal mass correction (now 4.0x for both heating and cooling modes)

Known Limitations

  • CTF Thermal Mass Architectural Limitation: The current CTF implementation uses a simplified 5R1C thermal network structure. For buildings with high thermal mass (heavy concrete, masonry), ±15-30% deviation may occur.

Performance

  • 5R1C: ~2,575 configs/sec
  • CTF: ~800-1,200 configs/sec
  • FD: ~500-800 configs/sec