Notifications
You must be signed in to change notification settings - Fork 1.5k
Feat/kaco nh3 hybrid template #33044
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
base: master
Are you sure you want to change the base?
Changes from 6 commits
656b438
07ae0fd
fabfc93
18b5814
40eca57
50d5f8d
28c00fb
4f44806
f590eee
5b3cf4a
6871ba3
File filter
Filter by extension
Conversations
Jump to
Diff view
Diff view
There are no files selected for viewing
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,195 @@ | ||
| template: kaco-nh3-hybrid | ||
| products: | ||
| - brand: KACO | ||
| description: | ||
| de: KACO Blueplanet Hybrid NH3 (abregelbar) | ||
| en: KACO Blueplanet Hybrid NH3 (curtailable) | ||
| group: generic | ||
| capabilities: ["battery-control", "curtail"] | ||
| params: | ||
| - name: usage | ||
| choice: ["grid", "pv", "battery"] | ||
| - name: modbus | ||
| choice: ["rs485"] | ||
| - name: modbusdeviceid | ||
| default: 3 | ||
| description: | ||
| de: Geräte-ID (Slave ID) | ||
| en: Device ID (Slave ID) | ||
| - name: baudrate | ||
| default: 9600 | ||
| type: choice | ||
| choice: [9600, 19200, 38400] | ||
| description: | ||
| de: Baudrate der RS485-Verbindung | ||
| en: Baud rate of RS485 connection | ||
|
hansenelectric marked this conversation as resolved.
|
||
| - name: battery | ||
| type: choice | ||
| choice: ["1", "2"] | ||
| required: true | ||
| usages: ["battery"] | ||
| description: | ||
| de: Batteriespeichernummer | ||
| en: Battery number | ||
| requirements: | ||
| description: | ||
| de: | | ||
| Modbus-RTU (RS485) Verbindung mit konfigurierbarer Baudrate (9600, 19200, 38400 Baud), | ||
| 8 Datenbits, 1 Stoppbit, keine Parität. | ||
| Der KACO NH3 muss sich im Grid-Feeding Modus befinden und Sunspec Model 704 (Generic Inverter Controls) unterstützen. | ||
| Für Batteriesteuerung: Zwei Batteriepakete (BMS1 + BMS2) jeweils mit einem Batteriezähler mit Batteriespeichernummer 1 und 2 anlegen. | ||
| Batteriekapazität: 30.72 kWh | Max. Lade-/Entladestrom: 30 A | ||
| Lade-/Entladeleistung wird dynamisch aus der Batteriespannung berechnet (P = U × 30A). | ||
| en: | | ||
| Modbus-RTU (RS485) connection with configurable baud rate (9600, 19200, 38400 baud), | ||
| 8 data bits, 1 stop bit, no parity. | ||
| KACO NH3 must be in Grid-Feeding mode and support SunSpec Model 704 (Generic Inverter Controls). | ||
| For battery control: add one battery meter each for two battery packs (BMS1 + BMS2), using battery number 1 and 2. | ||
| Battery capacity: 30.72 kWh | Max. charge/discharge current: 30 A | ||
| Charge/discharge power is calculated dynamically from battery voltage (P = U × 30A). | ||
| render: | | ||
| type: custom | ||
| {{- if eq .usage "grid" }} | ||
| power: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 2 }} | ||
| value: 203:W # Model 203 (Three Phase Meter) - Grid Power | ||
| {{- end }} | ||
| {{- if eq .usage "pv" }} | ||
| power: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 2 }} | ||
| value: 701:W # Model 701 (Inverter) - AC Power Output | ||
| energy: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 2 }} | ||
| value: 701:TotWhInj # Model 701 - Total Watt-hours Injected | ||
| scale: 0.001 | ||
| curtail: | ||
| source: sequence | ||
| set: | ||
| # Step 1: Set the power limit percentage (0-100%) | ||
| - source: sunspec | ||
| {{- include "modbus" . | indent 6 }} | ||
| value: 704:WMaxLimPct # Model 704 (Generic Inverter Controls) at address 50640 | ||
| # Step 2: Control enable/disable of the limit | ||
| - source: switch | ||
| switch: | ||
| - case: 100 # Uncurtailed (no limit) | ||
| set: | ||
| source: const | ||
| value: 0 # Disabled | ||
| set: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 14 }} | ||
| value: 704:WMaxLimPctEna # Model 704 at address 50639 | ||
| default: | ||
| source: const | ||
| value: 1 # Enabled | ||
| set: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 10 }} | ||
| value: 704:WMaxLimPctEna # Model 704 at address 50639 | ||
| curtailed: # Read back the current curtailment status | ||
| source: go | ||
| in: | ||
| - name: ena | ||
| type: bool | ||
| config: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 6 }} | ||
| value: 704:WMaxLimPctEna # Model 704 at address 50639 | ||
|
Member
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. drop the comments, they don't provide additional value
Author
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. okey. i put them in so i could remember where it was coming from. but okey. i can leave them out. |
||
| - name: limit | ||
| type: float | ||
| config: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 6 }} | ||
| value: 704:WMaxLimPct # Model 704 at address 50640 | ||
| script: | | ||
| percent := 100 | ||
| if ena { | ||
| percent = int(limit) | ||
| } | ||
| percent | ||
| {{- end }} | ||
| {{- if eq .usage "battery" }} | ||
| power: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 2 }} | ||
| value: {{ if eq .battery "2" }}714:Prt.2.DCW{{ else }}714:Prt.1.DCW{{ end }} # Model 714 (DC Module - Battery Power) | ||
|
sourcery-ai[bot] marked this conversation as resolved.
Outdated
|
||
| # Prt.1 = Battery 1, Prt.2 = Battery 2 via Model 714 (Multi-Port DC Module) | ||
| soc: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 2 }} | ||
| value: 802:SoC # Model 802 (Battery Base) - State of Charge | ||
| capacity: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 2 }} | ||
| value: 802:WHRtg # Model 802 - Battery nominal capacity in Wh (read from inverter) | ||
| minsoc: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 2 }} | ||
| value: 802:SoCMin # Model 802 - Minimum SOC limit % (read from inverter) | ||
| maxsoc: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 2 }} | ||
| value: 802:SoCMax # Model 802 - Maximum SOC limit % (read from inverter) | ||
| # Dynamic calculation of max charge/discharge power based on battery voltage | ||
| # Formula: Power (W) = Battery Voltage (V) × Max Current (30 A) | ||
| # Battery voltage varies with SoC (e.g., 300-330V for 6-series Dyness stack) | ||
| # This ensures accurate power limits throughout the charge cycle | ||
| maxchargepower: | ||
|
Member
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. pls keep it simple- too much magic
Author
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. hmm. i would like this limitation as the charging/discharging power is highly dependent on the battery voltage (for high voltage batteries). if it was a low voltage battery then it's more simpel.
Member
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. We're not doing this for any other (HV) battery sofar. Lets keep it consistent and simple. |
||
| source: go | ||
| in: | ||
| - name: voltage | ||
| type: float | ||
| config: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 6 }} | ||
| value: 802:V # Model 802 (Battery Base) - Battery Voltage | ||
| script: | | ||
| # Calculate max charge power: voltage × 30A (max current) | ||
| int(voltage * 30) | ||
| maxdischargepower: | ||
| source: go | ||
| in: | ||
| - name: voltage | ||
| type: float | ||
| config: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 6 }} | ||
| value: 802:V # Model 802 (Battery Base) - Battery Voltage | ||
| script: | | ||
| # Calculate max discharge power: voltage × 30A (max current) | ||
| int(voltage * 30) | ||
| batterymode: | ||
| source: switch | ||
| switch: | ||
| - case: 1 # normal | ||
| set: | ||
| source: const | ||
| value: 1 # Normal mode | ||
| set: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 10 }} | ||
| value: 802:ChaSt # Model 802 (Battery Base) at address 51003 - Charge State | ||
| - case: 2 # hold | ||
| set: | ||
| source: const | ||
| value: 6 # Holding mode | ||
| set: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 10 }} | ||
| value: 802:ChaSt # Model 802 at address 51003 | ||
| - case: 3 # charge | ||
| set: | ||
| source: const | ||
| value: 3 # Charging mode | ||
| set: | ||
| source: sunspec | ||
| {{- include "modbus" . | indent 10 }} | ||
| value: 802:ChaSt # Model 802 at address 51003 | ||
| default: | ||
| source: error | ||
| error: ErrNotAvailable | ||
| {{- end }} | ||