21 changes: 11 additions & 10 deletions IBPSA/Fluid/HeatPumps/ModularReversible/UsersGuide.mo
Original file line number Diff line number Diff line change
Expand Up @@ -40,7 +40,7 @@ package UsersGuide
They may be on/off and inverter driven;
</li>
<li>
They are able to reverse the operation between heating and cooling,
They are able to reverse the operation between heating and cooling,
and some systems even provide simultaneous heating and cooling capabilities;
</li>
<li>
Expand Down Expand Up @@ -118,8 +118,8 @@ to the section <b>Refrigerant cycle models</b>.
<!-- @include_Buildings
<li>
<a href=\"modelica://IBPSA.Fluid.HeatPumps.ModularReversible.TableData2DLoadDep\">
IBPSA.Fluid.HeatPumps.ModularReversible.TableData2DLoadDep</a>:
This is the recommended model for energy simulation and any use case where detailed
IBPSA.Fluid.HeatPumps.ModularReversible.TableData2DLoadDep</a>:
This is the recommended model for energy simulation and any use case where detailed
modeling of the heat pump onboard controls is not required.
</li>
-->
Expand Down Expand Up @@ -171,8 +171,8 @@ to the section <b>Refrigerant cycle models</b>.
<!-- @include_Buildings
<li>
<a href=\"modelica://IBPSA.Fluid.Chillers.ModularReversible.TableData2DLoadDep\">
IBPSA.Fluid.Chillers.ModularReversible.TableData2DLoadDep</a>:
This is the recommended model for energy simulation and any use case where detailed
IBPSA.Fluid.Chillers.ModularReversible.TableData2DLoadDep</a>:
This is the recommended model for energy simulation and any use case where detailed
modeling of the chiller onboard controls is not required.
</li>
-->
Expand Down Expand Up @@ -305,12 +305,13 @@ The following table summarizes the possible options.
<!-- @include_Buildings
<p>
Prefatory note: This section only applies to the models that do not include
onboard controls. The models that include onboard controls, such as
onboard controls. The models that include onboard controls, such as
<a href=\"modelica://IBPSA.Fluid.HeatPumps.ModularReversible.TableData2DLoadDep\">
IBPSA.Fluid.HeatPumps.ModularReversible.TableData2DLoadDep</a>,
rather expose a connector <code>TSet</code> representing the temperature setpoint.
rather expose a connector <code>THwSet</code> or <code>TChwSet</code> representing
the HW or CHW temperature setpoint.
</p>
-->
-->

<p>
The input <code>ySet</code> represents the relative compressor speed.
Expand Down Expand Up @@ -387,11 +388,11 @@ rather expose a connector <code>TSet</code> representing the temperature setpoin
the third dimension of the performance sensitivity is captured using
the part load ratio as a proxy variable for the actual capacity modulation observable.
This allows a unified modeling of various technologies such as
modulating the compressor speed, throttling the inlet guide vanes
modulating the compressor speed, throttling the inlet guide vanes
or staging a varying number of compressors.
This approach does not rely on any third-party dependency and is fully
supported by the existing classes from the Modelica Standard Library.
It is implemented in the modular heat pump and chiller models named
It is implemented in the modular heat pump and chiller models named
<code>TableData2DLoadDep</code>.
</p>

Expand Down