215 changes: 113 additions & 102 deletions bundles/org.openhab.binding.fronius/README.md

Large diffs are not rendered by default.

Original file line number Diff line number Diff line change
Expand Up @@ -12,6 +12,7 @@
*/
package org.openhab.binding.fronius.internal;

import java.util.Map;
import java.util.Set;

import org.eclipse.jdt.annotation.NonNullByDefault;
Expand Down Expand Up @@ -40,38 +41,38 @@ public class FroniusBindingConstants {
public static final ThingTypeUID THING_TYPE_BATTERY = new ThingTypeUID(BINDING_ID, "battery");

// Inverter channels
public static final String INVERTER_DATA_CHANNEL_DAY_ENERGY = "inverterdatachanneldayenergy";
public static final String INVERTER_DATA_CHANNEL_PAC = "inverterdatachannelpac";
public static final String INVERTER_DATA_CHANNEL_TOTAL = "inverterdatachanneltotal";
public static final String INVERTER_DATA_CHANNEL_YEAR = "inverterdatachannelyear";
public static final String INVERTER_DATA_CHANNEL_FAC = "inverterdatachannelfac";
public static final String INVERTER_DATA_CHANNEL_IAC = "inverterdatachanneliac";
public static final String INVERTER_DATA_CHANNEL_IDC = "inverterdatachannelidc";
public static final String INVERTER_DATA_CHANNEL_IDC2 = "inverterdatachannelidc2";
public static final String INVERTER_DATA_CHANNEL_IDC3 = "inverterdatachannelidc3";
public static final String INVERTER_DATA_CHANNEL_UAC = "inverterdatachanneluac";
public static final String INVERTER_DATA_CHANNEL_UDC = "inverterdatachanneludc";
public static final String INVERTER_DATA_CHANNEL_UDC2 = "inverterdatachanneludc2";
public static final String INVERTER_DATA_CHANNEL_UDC3 = "inverterdatachanneludc3";
public static final String INVERTER_DATA_CHANNEL_PDC = "inverterdatachannelpdc";
public static final String INVERTER_DATA_CHANNEL_PDC2 = "inverterdatachannelpdc2";
public static final String INVERTER_DATA_CHANNEL_PDC3 = "inverterdatachannelpdc3";
public static final String INVERTER_DATA_CHANNEL_DEVICE_STATUS_ERROR_CODE = "inverterdatadevicestatuserrorcode";
public static final String INVERTER_DATA_CHANNEL_DEVICE_STATUS_STATUS_CODE = "inverterdatadevicestatusstatuscode";
public static final String INVERTER_DATA_CHANNEL_DAY_ENERGY = "day-energy";
public static final String INVERTER_DATA_CHANNEL_PAC = "ac-power";
public static final String INVERTER_DATA_CHANNEL_TOTAL = "total-energy";
public static final String INVERTER_DATA_CHANNEL_YEAR = "year-energy";
public static final String INVERTER_DATA_CHANNEL_FAC = "ac-frequency";
public static final String INVERTER_DATA_CHANNEL_IAC = "ac-current";
public static final String INVERTER_DATA_CHANNEL_IDC = "dc-current";
public static final String INVERTER_DATA_CHANNEL_IDC2 = "dc-current-2";
public static final String INVERTER_DATA_CHANNEL_IDC3 = "dc-current-3";
public static final String INVERTER_DATA_CHANNEL_UAC = "ac-voltage";
public static final String INVERTER_DATA_CHANNEL_UDC = "dc-voltage";
public static final String INVERTER_DATA_CHANNEL_UDC2 = "dc-voltage-2";
public static final String INVERTER_DATA_CHANNEL_UDC3 = "dc-voltage-3";
public static final String INVERTER_DATA_CHANNEL_PDC = "dc-power";
public static final String INVERTER_DATA_CHANNEL_PDC2 = "dc-power-2";
public static final String INVERTER_DATA_CHANNEL_PDC3 = "dc-power-3";
public static final String INVERTER_DATA_CHANNEL_DEVICE_STATUS_ERROR_CODE = "error-code";
public static final String INVERTER_DATA_CHANNEL_DEVICE_STATUS_STATUS_CODE = "status-code";

// Power Flow channels
public static final String POWER_FLOW_P_GRID = "powerflowchannelpgrid";
public static final String POWER_FLOW_P_LOAD = "powerflowchannelpload";
public static final String POWER_FLOW_P_AKKU = "powerflowchannelpakku";
public static final String POWER_FLOW_P_PV = "powerflowchannelppv";
public static final String POWER_FLOW_AUTONOMY = "powerflowautonomy";
public static final String POWER_FLOW_SELF_CONSUMPTION = "powerflowselfconsumption";
public static final String POWER_FLOW_P_GRID = "grid-power";
public static final String POWER_FLOW_P_LOAD = "load-power";
public static final String POWER_FLOW_P_AKKU = "battery-power";
public static final String POWER_FLOW_P_PV = "solar-power";
public static final String POWER_FLOW_AUTONOMY = "autonomy";
public static final String POWER_FLOW_SELF_CONSUMPTION = "self-consumption";

public static final String POWER_FLOW_INVERTER_POWER = "powerflowinverterpower";
public static final String POWER_FLOW_INVERTER_SOC = "powerflowinvertersoc";
public static final String POWER_FLOW_INVERTER_POWER = "inverter-power";
public static final String POWER_FLOW_INVERTER_SOC = "battery-soc";

public static final String POWER_FLOW_BACKUP_MODE = "powerflowbackupmode";
public static final String POWER_FLOW_BATTERY_STANDBY = "powerflowbatterystandby";
public static final String POWER_FLOW_BACKUP_MODE = "backup-mode";
public static final String POWER_FLOW_BATTERY_STANDBY = "battery-standby";

// For backwards compatibility
public static final String POWER_FLOW_INVERTER_1_POWER = "powerflowinverter1power";
Expand All @@ -80,52 +81,105 @@ public class FroniusBindingConstants {
// Meter channels
public static final String METER_ENABLE = "enable";
public static final String METER_LOCATION = "location";
public static final String METER_CURRENT_AC_PHASE_1 = "currentacphase1";
public static final String METER_CURRENT_AC_PHASE_2 = "currentacphase2";
public static final String METER_CURRENT_AC_PHASE_3 = "currentacphase3";
public static final String METER_VOLTAGE_AC_PHASE_1 = "voltageacphase1";
public static final String METER_VOLTAGE_AC_PHASE_2 = "voltageacphase2";
public static final String METER_VOLTAGE_AC_PHASE_3 = "voltageacphase3";
public static final String METER_POWER_PHASE_1 = "powerrealphase1";
public static final String METER_POWER_PHASE_2 = "powerrealphase2";
public static final String METER_POWER_PHASE_3 = "powerrealphase3";
public static final String METER_POWER_SUM = "powerrealsum";
public static final String METER_POWER_FACTOR_PHASE_1 = "powerfactorphase1";
public static final String METER_POWER_FACTOR_PHASE_2 = "powerfactorphase2";
public static final String METER_POWER_FACTOR_PHASE_3 = "powerfactorphase3";
public static final String METER_ENERGY_REAL_SUM_CONSUMED = "energyrealsumconsumed";
public static final String METER_ENERGY_REAL_SUM_PRODUCED = "energyrealsumproduced";
public static final String METER_CURRENT_AC_PHASE_1 = "ac-current-phase-1";
public static final String METER_CURRENT_AC_PHASE_2 = "ac-current-phase-2";
public static final String METER_CURRENT_AC_PHASE_3 = "ac-current-phase-3";
public static final String METER_VOLTAGE_AC_PHASE_1 = "ac-voltage-phase-1";
public static final String METER_VOLTAGE_AC_PHASE_2 = "ac-voltage-phase-2";
public static final String METER_VOLTAGE_AC_PHASE_3 = "ac-voltage-phase-3";
public static final String METER_POWER_PHASE_1 = "real-power-phase-1";
public static final String METER_POWER_PHASE_2 = "real-power-phase-2";
public static final String METER_POWER_PHASE_3 = "real-power-phase-3";
public static final String METER_POWER_SUM = "real-power-sum";
public static final String METER_POWER_FACTOR_PHASE_1 = "power-factor-phase-1";
public static final String METER_POWER_FACTOR_PHASE_2 = "power-factor-phase-2";
public static final String METER_POWER_FACTOR_PHASE_3 = "power-factor-phase-3";
public static final String METER_ENERGY_REAL_SUM_CONSUMED = "real-energy-consumed";
public static final String METER_ENERGY_REAL_SUM_PRODUCED = "real-energy-produced";

// OhmPilot channels
public static final String OHMPILOT_POWER_REAL_SUM = "powerrealsum";
public static final String OHMPILOT_ENERGY_REAL_SUM_CONSUMED = "energyrealsumconsumed";
public static final String OHMPILOT_ENERGY_SENSOR_TEMPERATURE_CHANNEL_1 = "temperaturechannel1";
public static final String OHMPILOT_ERROR_CODE = "errorcode";
public static final String OHMPILOT_STATE_CODE = "statecode";
public static final String OHMPILOT_POWER_REAL_SUM = "real-power-sum";
public static final String OHMPILOT_ENERGY_REAL_SUM_CONSUMED = "real-energy-consumed";
public static final String OHMPILOT_ENERGY_SENSOR_TEMPERATURE_CHANNEL_1 = "temperature-1";
public static final String OHMPILOT_ERROR_CODE = "error-code";
public static final String OHMPILOT_STATE_CODE = "status-code";

// Battery channels
public static final String BATTERY_CAPACITY_MAXIMUM = "maximumCapacity";
public static final String BATTERY_DESIGNED_CAPACITY = "designedCapacity";
public static final String BATTERY_CURRENT_DC = "currentDc";
public static final String BATTERY_VOLTAGE_DC = "voltageDc";
public static final String BATTERY_CAPACITY_MAXIMUM = "maximum-capacity";
public static final String BATTERY_DESIGNED_CAPACITY = "designed-capacity";
public static final String BATTERY_CURRENT_DC = "dc-current";
public static final String BATTERY_VOLTAGE_DC = "dc-voltage";
public static final String BATTERY_STATE_OF_CHARGE = "soc";
public static final String BATTERY_STATUS_BATTERY_CELL = "status";
public static final String BATTERY_ENABLE = "enable";
public static final String BATTERY_TEMPERATURE_CELL = "temperature";
public static final String BATTERY_TIMESTAMP = "timestamp";

// Battery settings channels, provided through the inverter's config API
public static final String BATTERY_SOC_MIN_CHANNEL = "socMin";
public static final String BATTERY_SOC_MAX_CHANNEL = "socMax";
public static final String BATTERY_BACKUP_RESERVED_CHANNEL = "backupReservedCapacity";
public static final String BATTERY_BACKUP_CRITICAL_SOC_CHANNEL = "backupCriticalSoc";
public static final String BATTERY_CHARGE_FROM_GRID_CHANNEL = "chargeFromGrid";
public static final String BATTERY_SOC_MIN_CHANNEL = "soc-min";
public static final String BATTERY_SOC_MAX_CHANNEL = "soc-max";
public static final String BATTERY_BACKUP_RESERVED_CHANNEL = "backup-reserved-capacity";
public static final String BATTERY_BACKUP_CRITICAL_SOC_CHANNEL = "backup-critical-soc";
public static final String BATTERY_CHARGE_FROM_GRID_CHANNEL = "charge-from-grid";
public static final String BATTERY_CALIBRATION_CHANNEL = "calibration";
public static final String BATTERY_NIGHT_PRESERVATION_LIMIT_CHANNEL = "nightPreservationLimit";
public static final String BATTERY_NIGHT_PRESERVATION_LIMIT_CHANNEL = "night-preservation-limit";
public static final String BATTERY_MIN_CHARGE_POWER_CHANNEL = "min-charge-power";
public static final String BATTERY_MAX_CHARGE_POWER_CHANNEL = "max-charge-power";
public static final String BATTERY_MIN_DISCHARGE_POWER_CHANNEL = "min-discharge-power";
public static final String BATTERY_MAX_DISCHARGE_POWER_CHANNEL = "max-discharge-power";
public static final Set<String> BATTERY_TIME_OF_USE_CHANNELS = Set.of(BATTERY_MIN_CHARGE_POWER_CHANNEL,
BATTERY_MAX_CHARGE_POWER_CHANNEL, BATTERY_MIN_DISCHARGE_POWER_CHANNEL, BATTERY_MAX_DISCHARGE_POWER_CHANNEL);
public static final Set<String> BATTERY_SETTINGS_CHANNELS = Set.of(BATTERY_SOC_MIN_CHANNEL, BATTERY_SOC_MAX_CHANNEL,
BATTERY_BACKUP_RESERVED_CHANNEL, BATTERY_BACKUP_CRITICAL_SOC_CHANNEL, BATTERY_CHARGE_FROM_GRID_CHANNEL,
BATTERY_CALIBRATION_CHANNEL, BATTERY_NIGHT_PRESERVATION_LIMIT_CHANNEL);

/**
* Maps the ids of deprecated channels to the ids of the channels replacing them.
* The deprecated channels stay functional, so that existing setups keep working.
*/
public static final Map<String, String> DEPRECATED_CHANNEL_IDS = Map.ofEntries(
Map.entry("inverterdatachannelpac", INVERTER_DATA_CHANNEL_PAC),
Map.entry("inverterdatachannelpdc", INVERTER_DATA_CHANNEL_PDC),
Map.entry("inverterdatachannelpdc2", INVERTER_DATA_CHANNEL_PDC2),
Map.entry("inverterdatachannelpdc3", INVERTER_DATA_CHANNEL_PDC3),
Map.entry("inverterdatachanneldayenergy", INVERTER_DATA_CHANNEL_DAY_ENERGY),
Map.entry("inverterdatachanneltotal", INVERTER_DATA_CHANNEL_TOTAL),
Map.entry("inverterdatachannelyear", INVERTER_DATA_CHANNEL_YEAR),
Map.entry("inverterdatachannelfac", INVERTER_DATA_CHANNEL_FAC),
Map.entry("inverterdatachanneliac", INVERTER_DATA_CHANNEL_IAC),
Map.entry("inverterdatachannelidc", INVERTER_DATA_CHANNEL_IDC),
Map.entry("inverterdatachannelidc2", INVERTER_DATA_CHANNEL_IDC2),
Map.entry("inverterdatachannelidc3", INVERTER_DATA_CHANNEL_IDC3),
Map.entry("inverterdatachanneluac", INVERTER_DATA_CHANNEL_UAC),
Map.entry("inverterdatachanneludc", INVERTER_DATA_CHANNEL_UDC),
Map.entry("inverterdatachanneludc2", INVERTER_DATA_CHANNEL_UDC2),
Map.entry("inverterdatachanneludc3", INVERTER_DATA_CHANNEL_UDC3),
Map.entry("inverterdatadevicestatuserrorcode", INVERTER_DATA_CHANNEL_DEVICE_STATUS_ERROR_CODE),
Map.entry("inverterdatadevicestatusstatuscode", INVERTER_DATA_CHANNEL_DEVICE_STATUS_STATUS_CODE),
Map.entry("powerflowchannelpgrid", POWER_FLOW_P_GRID),
Map.entry("powerflowchannelpload", POWER_FLOW_P_LOAD),
Map.entry("powerflowchannelpakku", POWER_FLOW_P_AKKU), Map.entry("powerflowchannelppv", POWER_FLOW_P_PV),
Map.entry("powerflowautonomy", POWER_FLOW_AUTONOMY),
Map.entry("powerflowselfconsumption", POWER_FLOW_SELF_CONSUMPTION),
Map.entry("powerflowinverterpower", POWER_FLOW_INVERTER_POWER),
Map.entry("powerflowinvertersoc", POWER_FLOW_INVERTER_SOC),
Map.entry("maximumCapacity", BATTERY_CAPACITY_MAXIMUM),
Map.entry("designedCapacity", BATTERY_DESIGNED_CAPACITY), Map.entry("currentDc", BATTERY_CURRENT_DC),
Map.entry("voltageDc", BATTERY_VOLTAGE_DC), Map.entry("currentacphase1", METER_CURRENT_AC_PHASE_1),
Map.entry("currentacphase2", METER_CURRENT_AC_PHASE_2),
Map.entry("currentacphase3", METER_CURRENT_AC_PHASE_3),
Map.entry("voltageacphase1", METER_VOLTAGE_AC_PHASE_1),
Map.entry("voltageacphase2", METER_VOLTAGE_AC_PHASE_2),
Map.entry("voltageacphase3", METER_VOLTAGE_AC_PHASE_3), Map.entry("powerrealphase1", METER_POWER_PHASE_1),
Map.entry("powerrealphase2", METER_POWER_PHASE_2), Map.entry("powerrealphase3", METER_POWER_PHASE_3),
Map.entry("powerrealsum", METER_POWER_SUM), Map.entry("powerfactorphase1", METER_POWER_FACTOR_PHASE_1),
Map.entry("powerfactorphase2", METER_POWER_FACTOR_PHASE_2),
Map.entry("powerfactorphase3", METER_POWER_FACTOR_PHASE_3),
Map.entry("energyrealsumconsumed", METER_ENERGY_REAL_SUM_CONSUMED),
Map.entry("energyrealsumproduced", METER_ENERGY_REAL_SUM_PRODUCED),
Map.entry("temperaturechannel1", OHMPILOT_ENERGY_SENSOR_TEMPERATURE_CHANNEL_1),
Map.entry("statecode", OHMPILOT_STATE_CODE), Map.entry("errorcode", OHMPILOT_ERROR_CODE));

// List of all Urls
public static final String INVERTER_REALTIME_DATA_URL = "%SCHEME%://%IP%/solar_api/v1/GetInverterRealtimeData.cgi?Scope=Device&DeviceId=%DEVICEID%&DataCollection=CommonInverterData";
public static final String INVERTER_INFO_URL = "%SCHEME%://%IP%/solar_api/v1/GetInverterInfo.cgi";
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -27,6 +27,7 @@
import org.openhab.binding.fronius.internal.api.FroniusCommunicationException;
import org.openhab.binding.fronius.internal.api.FroniusUnauthorizedException;
import org.openhab.binding.fronius.internal.api.dto.inverter.batterycontrol.ScheduleType;
import org.openhab.binding.fronius.internal.api.dto.inverter.batterycontrol.TimeOfUseRecord;
import org.openhab.binding.fronius.internal.handler.FroniusBatteryHandler;
import org.openhab.core.automation.annotation.ActionInput;
import org.openhab.core.automation.annotation.ActionOutput;
Expand Down Expand Up @@ -261,6 +262,25 @@ public static boolean setBackupReservedBatteryCapacity(ThingActions actions, Per
return toFroniusBatteryActions(actions).setBackupReservedBatteryCapacity(percent);
}

public static TimeOfUseRecord[] getTimeOfUseSchedules(ThingActions actions) {
return toFroniusBatteryActions(actions).getTimeOfUseSchedules();
}

@RuleAction(label = "@text/actions.get-time-of-use-schedules.label", description = "@text/actions.get-time-of-use-schedules.description")
public @ActionOutput(type = "org.openhab.binding.fronius.internal.api.dto.inverter.batterycontrol.TimeOfUseRecord[]", label = "Schedules") TimeOfUseRecord[] getTimeOfUseSchedules() {
FroniusBatteryControl batteryControl = getBatteryControl();
if (batteryControl != null) {
try {
return batteryControl.getTimeOfUse().records();
} catch (FroniusCommunicationException e) {
logger.warn("Failed to read time of use schedules", e);
} catch (FroniusUnauthorizedException e) {
logger.warn("Failed to read time of use schedules: Invalid username or password");
}
}
return new TimeOfUseRecord[0];
}

@Override
public void setThingHandler(@Nullable ThingHandler handler) {
if (handler instanceof FroniusBatteryHandler h) {
Expand Down