22 changes: 21 additions & 1 deletion drivers/frequency/adf4377/README.rst
Original file line number Diff line number Diff line change
Expand Up @@ -110,6 +110,16 @@ by default to 1023. This can be configured using the **adf4377_set_bleed_word**
API, by providing the bleed word as a parameter on 10 bits. The current
configuration can be read out using **adf4377_get_bleed_word**.

Bleed Delay Configuration
-------------------------

Instead of programming the raw bleed word, the bleed current can also be
expressed as an output delay. The **adf4377_set_bleed_delay** API accepts the
desired delay in femtoseconds (a negative value selects the opposite polarity)
and translates it into the corresponding bleed word based on the charge pump
current and PFD frequency. The current configuration can be read back in
femtoseconds using **adf4377_get_bleed_delay**.

Output Frequency Configuration
------------------------------

Expand Down Expand Up @@ -144,6 +154,13 @@ used.

By default only channel 1 is enabled.

Output Inversion Configuration
------------------------------

The output of each channel can be inverted using the **adf4377_set_channel_inv**
API, by providing the channel number and the desired inversion value (0 or 1).
The current configuration can be read out using **adf4377_get_channel_inv**.

SYSREF Output Configuration
---------------------------
There are two distinct ways to configure the SYSREF output:
Expand Down Expand Up @@ -294,6 +311,8 @@ therefore most of the attributes will be device attributes.
The attributes are:

* bleed_current - is the adjustment value for the set charge pump current.
* bleed_delay - is the bleed current expressed as an output delay in
femtoseconds.
* charge_pump_current - is the current set in your design.
* charge_pump_current_available - lists the available and predefined charge
pump currents of the ADF4377.
Expand Down Expand Up @@ -321,10 +340,11 @@ The channels are:
* output altvoltage0 - corresponding to channel 1 on the device
* output altvoltage1 - corresponding to channel 2 on the device

Each channel has 2 individual attributes:
Each channel has 3 individual attributes:

* en - enables the channel.
* output_power - determines the output power of the channel between 0 and 15.
* inv - inverts the channel output.

Each channel has 2 common attributes:

Expand Down